Adaptive Bi-Level Ventilation with Leak Compensation

Adaptive Bi-Level is an assist control/pressure control ventilation mode with additional termination criteria based on percentage of peak flow.This capability allows ventilation in the presence of high leaks such as with tracheostomy, cuffless endotracheal tube and mask ventilation.

Incorporates the entire recommended feature set for NIPPV
Leak compensation for better patient synchrony. Built in FiO2 blender. Waveform display providing visual feedback on patient interface. No CO2 rebreathing. Alarms tailored to NIPPV. Portability in an oxygen conserving design. True tidal volume measurement. These features are not found together in any other ventilator that is capable of acute care support making the iVent201 ideal for your NIPPV needs!

Two-in-One Upgrade
The iVent201 software-based platform can be easily upgraded so it is able to offer the most up-to-date features today and in the future.

Transportability
Weighing 22 lbs (10 kg) the iVent201, with it's self-contained turbine and internal battery, is one of the only truly transportable critical care ventilators.

Patient Comfort
The iVent201 Adaptive Bi-Level option is designed to improve patient comfort during mask ventilation. The use of an exhalation valve reduces CO2 rebreathing and therefore enhances patient comfort. In addition, extended rise time control and termination of the breath based on flow or I-time improves patient synchronization.

Versatility
The iVent201 can be tailored for multiple applications from intensive care to the ER and home care use. The only ventilator on the market with both an CBRN filter and an internal battery -- it's ideal for emergency rescue and field hospital situations.

Ease of Use
The iVent201 provides a single solution for both mask and intubated ventilation. Utilizing the same circuit and ventilator simplifies the task of transferring a patient between invasive and face mask modes.

(CBRN) Chemical, Biological, Radiological and Nuclear iVent is a trademark of VersaMed.
Specifications

Adaptive Bi-Level Performance and
Controlled Parameters
Respiratory Rate
Tidal Volume
P-High
P-Low
Inspiratory Time
Vpeak % Term
Rise Time
Peak Flow
Oxygen Mix (F1O2)
Pressure Trigger
Flow Trigger
1 to 80 bpm
50 to 2000 ml
1 to 60 cmH2O
0 to 30 cmH2O
0.3 to 3.0 seconds
10% to 90%
0.1 to 1.5 seconds
1 to 120 L/min
21% to 100%
-0.5 to -20 cm H2O + OFF
1 to 20 L/min + OFF
Adaptive Bi-Level Monitoring and
Displayed Parameters
Airway Pressure (analog bar graph & numerical PIP)
Total Breath Rate
Estimated Tidal Volume
Estimate Leak
P-High
P-Low
Peak Flow
Inspiratory Time
I:E Ratio
Minute Volume
Electrical Power Source (external / internal)
Battery Level
Real Time Pressure and Flow Waveforms
Trending
Breath-by-Breath Browse Feature
Adjustable Alarms
Respiratory Rate (high / low)
Minute Volume (high / low)
Apnea (0 to 120 seconds)
F1O2 (high / low)
Pressure (high / low)
Leak (0 to 100% / off)
Size and Weight
Height
Width
Depth
Weight
Screen
13" (33 cm)
9.5" (24 cm)
10.3" (26 cm)
22 lbs (10 kg)
8.4" diagonal
Power Supply
External AC

External DC

Internal Battery

Operating Time
100 to 240 V, 50 to 60 Hz, Max 2.0 A
12 to 15 V (Optional: 10 t0 30 V), Max 8.5 A
Seal Lead-Acid 12 V (7.2 Ah) -- rechargeable
1 to 2 hours (depending on ventilation parameters)
Oxygen (enrichment) Supply
High Pressure Supply
Low Pressure
40 to 60 psi (2.8 to 4.2 bar)
Max 80 L/min or 0.5 psi
External Interface
Remote Monitor (VGA)
RS-232 Serial Port, 9 pin
Remote Alarm Connector 
Standards and Safety Requirements
Meets the requirements of:
ASTM F1100-90
CSA C22.2 No. 601.1 / 601.2
IEC 60601-1
IEC 60601-1-2
EN 60601-2-12
EN 794-1 / 2 / 3
ISO 10651-1 / 2 / 3
UL 2601.1
Main Screen

 

Monitor Screen

 

Home Care Screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VersaMed Medical Equipment.com